Section 12: Resisting fire spread over roof coverings

Share

Section 12: Resisting fire spread over roof coverings

Introduction

12.1 ‘Roof covering’ describes one or more layers of material, but not the roof structure as a whole.

12.2 Provisions for the fire properties of roofs are given in other parts of this document.

a. Requirement B1 – for roofs that are part of a means of escape.

b. Requirement B2 – for the internal surfaces of rooflights as part of internal linings.

c. Requirement B3 – for roofs that are used as a floor and for roofs passing over a compartment wall.

d. Section 11 – the circumstances in which a roof is subject to the provisions for space separation.

Separation distances

12.3 Separation distance is the minimum distance from the roof, or part of the roof, to the relevant boundary (paragraph 11.4). Table 12.1 sets out separation distances by the type of roof covering and the size and use of the building.
In addition, roof covering products (and/or materials) defined in Commission Decision 2000/553/ EC of 6 September 2000, implementing Council Directive 89/106/EEC, can be considered to fulfil all of the requirements for the performance characteristic ‘external fire performance’ without the need for testing, provided that any national provisions on the design and execution of works are fulfilled, and can be used without restriction.

12.4 The performance of rooflights is specified in a similar way to the performance of roof coverings. Plastic rooflights may also be used.

Plastic rooflights

12.5 Table 12.2 and Diagram 12.1 set the limitations for using plastic rooflights whose lower surface has a minimum class D-s3, d2 rating.

12.6 Table 12.3 sets the limitations for using thermoplastic materials with a TP(a) rigid or TP(b) (see also Diagram 12.1) classification. The method of classifying thermoplastic materials is given in Appendix B.

12.7 Other than for the purposes of Diagram 5.2, polycarbonate or uPVC rooflights achieving a minimum rating of class C-s3, d2 can be regarded as having a BROOF(t4) classification.

Unwired glass in rooflights

12.8 When used in rooflights, unwired glass a minimum of 4mm thick can be regarded as having a BROOF(t4) classification.

Thatch and wood shingles

12.9 If the performance of thatch or wood shingles cannot be established, they should be regarded as having an EROOF(t4) classification in Table 12.1.

NOTE: Consideration can be given to thatched roofs being closer to the relevant boundary than shown in Table 12.1 if, for example, all of the following precautions (based on the LABC publication Thatched Buildings (the Dorset Model): New Properties and Extensions) are incorporated in the design.

a. The rafters are overdrawn with construction having not less than 30 minutes’ fire resistance.

b. The guidance given in Approved Document J is followed.

c. The smoke alarm installation (see Section 1) extends to the roof spaces.

general G6
Diagram 12.1 Limitations on spacing and size of plastic rooflights that have a class D-s3, d2 or TP(b) lower surface

general G6
Table 12.1 Limitations on roof coverings

general G6
Table 12.2 Class D-s3, d2 plastic rooflights: limitations on use and boundary distance

general G6
Table 12.3 TP(a) and TP(b) thermoplastic rooflights: limitations on use and boundary distance

Requirement B5: Access and facilities for the fire service

These sections deal with the following requirement from Part B of Schedule 1 to the Building Regulations 2010.

Requirement

Requirement

Access and facilities for the fire service

B5. (1) The building shall be designed and constructed so as to provide reasonable facilities to assist fire fighters in the protection of life.

(2) Reasonable provision shall be made within the site of the building to enable fire appliances to gain access to the building.

Limits on application

Intention

Provisions covering access and facilities for the fire service are to safeguard the health and safety of people in and around the building. Their extent depends on the size and use of the building. Most firefighting is carried out within the building. In the Secretary of State’s view, requirement B5 is met by achieving all of the following.

a. External access enabling fire appliances to be used near the building.

b. Access into and within the building for firefighting personnel to both:

i. search for and rescue people

ii. fight fire.

c. Provision for internal fire facilities for firefighters to complete their tasks.

d. Ventilation of heat and smoke from a fire in a basement.

If an alternative approach is taken to providing the means of escape, outside the scope of this approved document, additional provisions for firefighting access may be required. Where deviating from the general guidance, it is advisable to seek advice from the fire and rescue service as early as possible (even if there is no statutory duty to consult).

External works Fire safety Ventilation Roof Heat pumps External insulation Cavity wall insulation Wall ties Air to water heat pump Air to air heat pump Air to ground heat pump IS 440 Roof insulation Suspended floor Time and temperature Fire stopping Fire mastic Fire wraps Fire board Tongue and groove Building energy rating Energy performance certificate External wall insulation Roof lights External doors Fire doors Internal doors Wall tiles Floor tiles Ventilation Mechanical ventilation Natural ventilation Fire cable